Memolub Connect Pro Tech Specs

MEMOLUB CONNECT SERIES KNOWLEDGE BASE

Dimensions

120CC

Grease / Oil Cartridge

120cc I 4oz
Memolub Connect Series Dimentions 120

240CC

Grease / Oil Cartridge

240cc I 8.1oz
Memolub Connect Series Dimentions 240

480CC

Grease / Oil Cartridge

480cc I 16.2oz
Memolub Connect Series Dimentions 480

OIL R-500

Refillable Oil Reservoir

500cc I 16.9oz
Memolub Connect Series Dimentions 500 R

Precautions

  • Do not open the housing: loaded spring
  • Hold MEMOLUB® down during manual checks
  • Leq <70 dB
  • Use MEMOLUB® only for greasing machinery
  • Use only lubricant cartridges and batteries recommended by the manufacturer
Memolub Visio Warnings

Settings & Feedback

FREQUENCY SETTINGS

WHEEL POSITION DOSING PERIODICITY MAX. DAILY OUTPUT* REFILLING FREQUENCY VS. CARTRIDGE CONTENT (120CC) REFILLING FREQUENCY VS. CARTRIDGE CONTENT (240CC) REFILLING FREQUENCY VS. CARTRIDGE CONTENT (480CC)
0 External (Interface / App)
1 48 hours 0.3 cc/day 12 months 24 months** 48 months**
2 24 hours 0.6 cc/day 6 months 12 months 24 months**
3 16 hours 0.9 cc/day 4 months 8 months 16 months**
4 12 hours 1.2 cc/day 3 months 6 months 12 months
5 8 hours 1.8 cc/day 2 months 4 months 8 months
6 6 hours 2.4 cc/day 1.5 month 3 months 6 months
7 4 hour 3.6 cc/day 1 month 2 months 4 months
8 2 hour 7.2 cc/day 0.5 month 1 month 2 months
9 1 hour 14.4 cc/day 0.25 month 0.5 month 1 month

*Maximum daily output without stroke washers.

** Please consider lubricant expiry date for long cartridge lifetimes.

VOLUME SETTINGS [cm³/day]

By using stroke washers you can adjust the amount of lubricant discharged per pumping cycle.

NUMBER OF STROKE WASHERS WHEEL POSITION
0 1 2 3 4 5 6 7 8 9
- External (Interface / App) 0.3 0.6 0.9 1.2 1.8 2.4 3.6 7.2 14.4
External (Interface / App) 0.28 0.56 0.84 1.12 1.7 2.2 3.4 6.7 13.5
+ External (Interface / App) 0.26 0.52 0.79 1.04 1.62 2.1 3.15 6.3 12.6
2 + External (Interface / App) 0.24 0.49 0.73 0.98 1.46 1.95 2.92 5.85 11.7
3 + External (Interface / App) 0.22 0.45 0.67 0.9 1.35 1.8 2.7 5.4 10.8
4 + External (Interface / App) 0.2 0.41 0.62 0.82 1.23 1.65 2.47 4.95 9.9
5 + External (Interface / App) 0.18 0.37 0.55 0.74 1.1 1.5 2.2 4.5 9
6 + External (Interface / App) 0.17 0.34 0.5 0.68 1 1.35 2.02 4.05 8.1

*The circlip must always be added on top of the washers.

The circlip must always be added on top of the washers.

COLOR STATUS
The pumping cycle was completed successfully, or a test run was initiated via the pushbutton.
The batteries are low, or the lubricant cartridge is empty.
The gearbox or motor is damaged or malfunctioning, or the pipe may be clogged.
A data connection has been established successfully.

REMOTE INSTALLATION DISTANCES

TYPE OF INSTALLATION MAXIMUM DISTANCE
Single point 8m
Multipoint with 2 outlets 6m
Multipoint with 4 outlets

LEARNING PERIOD

The Memolub Connect Pro are equipped with advanced machine learning capabilities, allowing it to account for environmental conditions when calculating its status. A learning period of 20 cycles is required, during which the lubricator must remain in the same environment without any changes to its position, fastening, support, or grease type. If any of these parameters are altered, the learning process can be reset by pressing and holding the pushbutton for more than 5 seconds.

CABLE

MEMOLUB CONNECT PRO

The Connect Pro is delivered with a 6 x 0.25mm² cable with a 6DIN M16 female connector.

DESCRIPTION
1. EXTERNAL INPUT (OPTOCOUPLER INPUT +)
2. EXTERNAL INPUT (OPTOCOUPLER INPUT -)
3. POWER SUPPLY + (24VAC/DC)*
4. STATUS OUTPUT (OPTOCOUPLER COLLECTOR)
5. STATUS OUTPUT (OPTOCOUPLER EMITTER)
6. POWER SUPPLY - (0VDC)

* Operating voltage ranges from 6 to 36 VDC

Specifications

General

MEMOLUB® CONNECT PRO
Power Source Battery / External
Voltage 4.5V DC (3x1.5V DC AA) OR 24V
Communication Protocol LoRa-Wan + Bluetooth
Display External (via app and cloud interface)
Short circuit protection Yes
Stroke duration 8 seconds
Minimum stroke interval 15 minutes

LoRa-Wan

MEMOLUB® CONNECT PRO
Version 1.1.4
Supported Frequency Plans EU863-870, AU915-928, US902-928,
Range (outdoor, line of sight) 1km*

* Range based on field tests conducted in an urban environment using a gateway equipped with a 3 dBi antenna.

Bluetooth

MEMOLUB® CONNECT PRO
Version 5.2
Frequency 2,4 GHz
Range (indoor, office environment) 30m
Range (outdoor, line of sight) 150m

INSTALLATION GUIDELINES

DIRECT INSTALLATION

  • 1

    B1

    Prime lube point and remove nipple.

  • 2

    B2

    Install VISIO Base using a strong threadlocker (BSP 1/4).

  • 3

    B3

    With setting key, choose wheel position according to "Settings" table above.

  • 4

    B4

    Align the pin of VISIO Module with the notch of VISIO Base.

  • 5

    B5

    Screw tightly keeping the assemly aligned.

  • 6

    B6

    VISIO initializes, flashes each color on, and makes one expulsion. Green lights confirm normal operation.

REMOTE INSTALLATION

  • 1

    C1

    Prime lube point and remove nipple.

  • 2

    C2

    Secure the mounting bracket.

  • 3

    C3

    Install VISIO Base and F1/4 fitting on bracket using a strong threadlocker.

  • 4

    C4

    Install BSP 1/8 fitting on lube point.

  • 5

    C5

    Cut hose to required size.

  • 6

    C6

    Insert hose into bracket's quick fitting.

  • 7

    C7

    Insert hose into lube point's quick fitting.

  • 8

    C8

    With setting key, choose wheel position according to "Settings" table above.

  • 9

    C9

    Align the pin of VISIO Module with the notch of VISIO Base.

  • 10

    C10

    Screw tightly keeping the assembly aligned.

  • 11

    C12

    VISIO initializes, flashes each color on, and makes one expulsion. Green lights confirm normal operation.

MULTIPOINT INSTALLATION

  • 1

    D1

    Prime lube point and remove nipple.

  • 2

    D2

    Secure the mounting bracket.

  • 3

    D3

    Install VISIO Base and F1/4 fitting on bracket using a strong threadlocker.

  • 4

    D4

    Install BSP 1/8 fitting on lube point.

  • 5

    D5

    Cut the hoses to required size.

  • 6

    D6

    Insert hoses into bracket's quick fittings.

  • 7

    D7

    Insert hoses into lube points' quick fittings.

  • 8

    D8

    With setting key, choose wheel position according to "Settings" table above.

  • 9

    D9

    Align the pin of VISIO Module with the notch of VISIO Base.

  • 10

    D10

    Screw tightly keeping the assembly aligned.

  • 11

    D12

    VISIO initializes, flashes each color on, and makes one expulsion. Green lights confirm normal operation.

CLOUD INTERFACE

MOBILE APP

PUSH BUTTON

TEST YOUR MEMOLUB / FORCE EXPULSION

  • 1

    E2

    Locate the push button on the bottom of the memo

  • 2

    E2

    Push the button

  • 3

    E4

    VISIO initializes, flashing each color on successively.

  • 4

    E5

    VISIO makes 1 expulsion.

  • 5

    E6

    After scanning all parameters, VISIO flashes green lights in case of normal operation. For any other colors, please refer to the FAQ section.

CARTRIDGE (RE)PLACEMENT GUIDELINES

  • 1

    A1

    Remove VISIO Module from VISIO Base.

  • 2

    A2

    Open VISIO Module (fingers on ribs). Remove the used cartridge, if any.

  • 3

    A3

    Prime VISIO Pump.

  • 4

    A4

    Insert new battery pack and seal. NOTE: the battery seal can be removed for 480cc cartridges

  • 5

    A5

    Squeeze air out of the cartridge.

  • 6

    A6

    Replace the cartridge on VISIO Pump.

  • 7

    A7

    Close and lock VISIO Module (fingers on ribs).

  • 8

    A8

    Align the pin of VISIO Module with the notch of VISIO Base.

  • 9

    A9

    Screw tightly keeping the assembly aligned.

  • 10

    A10

    VISIO initializes, flashes each color on, and makes one expulsion. Green light confirms proper functioning.

EXTERNAL POWER CONNECTION

INSTALLING THE CONNECTOR (CONNECT PRO ONLY)

  • 1

    Visio E Pconnector Installation1

    Locate the M4 set screw on the CONNECT PRO BASE rotary coupling. Screw it tightly.

  • 2

    Visio E Pconnector Installation2bis

    Screw tightly the CONNECT PRO pump & base on the bracket elbow

  • 3

    Visio E Pconnector Installation3

    Release the rotary coupling by unscrewing the M4 screw.

  • 4

    Visio E Pconnector Installation4

    Rotate the CONNECT PRO pump & base assembly clockwise, until the connector socket is outside the bracket.

  • 5

    Visio E Pconnector Installation5

    Check that the cable plug can engage properly on the connector socket

  • 6

    Visio E Pconnector Installation6

    Keeping the plug engaged, secure the M4 set screw tightly.

  • 7

    Visio E Pconnector Installation7

    The rotary coupling is now set. When disassembling/reassembling pump and base for maintenance pruposes, the connector will always find the same place.

REMOTE CONTROL

INTERMITTENT MODE

MEMOLUB VISIO PRO

DESCRIPTION SIGNAL
INPUT SIGNAL (FROM CUSTOMER PLC/TIMER)
OUTPUT SIGNAL "BUSY" (TO CUSTOMER PLC)
PUMP OUTLET (TO LUBRICATION)
OUTPUT SIGNAL "DEFAULT" (TO CUSTOMER PLC)

CONTINUOUS MODE

MEMOLUB VISIO PRO

DESCRIPTION SIGNAL
INPUT SIGNAL (FROM CUSTOMER PLC/TIMER)
OUTPUT SIGNAL "BUSY" (TO CUSTOMER PLC)
PUMP OUTLET (TO LUBRICATION)
OUTPUT SIGNAL "DEFAULT" (TO CUSTOMER PLC)

FAQ

  • Nothing happens after screwing the module on the base.

    • The pin of the module is possibly not proper aligned with the notch of the base. Unscrew the module from the base, align correctly and screw it again.
    • VISIO Module is not tightly screwed to VISIO Base. Turn it clockwise until stop.
    • There is possibly no battery inside the module. Insert 3x 1,5 VDC AA batteries to resolve the issue.
    • There is possibly something obstructing the communication between the base and the module contacts. Unscrew the module from the base, remove any dust or obstacles from the base and the module contacts and screw back together tightly.
  • The touchpad does not work after initialisation was completed successfully.

    Your MEMOLUB® VISIO possibly initialized in an unstable environment. Unscrew the base from the module and screw again to reset the system. Wait until one expulsion is performed and you observe green lights, indicating the initialization is complete.

  • The red lights are blinking periodically.

    • There is possibly a too high back pressure present in the system. Inspect your downstream piping to remove any clogging or jam. Activate the touchpad and check for at least 2 expulsions if the systems operate fine.
    • There is possibly something obstructing the communication between the base and the module contacts. Unscrew the module from the base, remove any dust or obstacles from the base and the module contacts and screw back together tightly.
    • The motor is broken. Replacement of the module is necessary.
  • The yellow lights are blinking periodically.

    • There is possibly something obstructing the communication between the base and the module contacts. Unscrew the module from the base, remove any dust or obstacles from the base and the module contacts and screw back together tightly.
    • The batteries are empty. Replacement of the battery pack is necessary.
  • The blue lights are blinking periodically.

    • The cartridge is possibly out of grease. Replacement of the cartridge is necessary.
    • The system is not primed. Prime the system using a manual grease pump.
    • The system is operating out of its minimum and maximum temperature range. Please make sure the system is operating within the recommended temperature range.

REGULATORY INFORMATION

SYMBOL DESCRIPTION
This product is compliant with Directives 2006/42/EC (Machinery). The relevant Declaration of Conformity is available here.
This product is compliant with UK regulations 2008 No. 1597 (Supply of Machinery). The relevant Declaration of Conformity is available here.
This product is compliant with customs union technical regulation TR CU 010/2011 (safety of machines and equipment). The relevant Declaration of Conformity is available here.
The WEEE symbol is attached to the product in compliance with the EU directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE). It is intended to deter the improper disposal of this product and to promote reuse and recycling.
The packaging material can be recycled. Please arrange for the environmental appropriate disposal of the packaging.