Memolub DS Tech Specs Grey

Memolub® DS KNOWLEDGE BASE

Dimensions

Memolub DS Dimentions 01

Memolub DS Dimentions 02

INSIDE THE BOX

Memolub DS Control Unit

Memolub DS Control Unit

Memolub ds pump

Memolub DS Pump

Memolub DS Follow Plate

Compression plate

Case Studies Placeholder

Closure lid

Memolub DS Remote

Remote control

MEMOLUB DS PUMP

This step involves correctly placing the prepared pump assembly in the container so that it only has to be connected. You must use the shovel plate, the pump and the lid whose sizes are adapted to the chosen container. For more information on the sizes available, consult your MEMOLUB® distributor.

Before placing the pump in the container, you must check the following points otherwise the shovel plate may not work properly.

DS pump placement container

TECHNICAL DATA

MEMOLUB DS PUMP 18kg MEMOLUB DS PUMP 50kg
Pump ratio 20/1
Input air pressure 6 bar
T1/T2 thread F 1/8"G BSP
T1 Tubing ø 6-8mm
T2 Tubing ø 4-6mm
Lube output thread M 1/2"G
Diameter rod ø 30mm
Expulsion per stroke 4,5cm³
Length rod 530mm 780kg
Packaging / container 18-30kg 50-60kg
Weight dosing pump 5,10kg 6,50kg

The DS pump's work cycle is created by the alternating movement of the piston.

The piston's movements are caused by the air throughput, controlled by the timer in the black box. A work cycle is composed of two work phases (T1 and T2):

Memolub DS T1

T1 (piston descending phase): internal transfer of the lubricant towards the expulsion chamber.

Memolub DS T2

T2 (piston ascending phase): simultaneous aspiration and expulsion of the lubricant.

MEMOLUB DS CONTROL UNIT

The MEMOLUB® DS CONTROL UNIT Unit is a simple electronic system for managing the expulsion of the lubricant. A MEMOLUB® DS CONTROL UNIT can manage several pumps. Note that it is possible to connect a visual feedback via a distributor system with an optional on-off switch. The control unit comes in 2 versions: 24VDC or 220 VAC 50Hz.

The electronic box is composed of a circuit card and a solenoid. The solenoid powers the pump's "IN1" and "IN2" inputs alternately via two pipes corresponding to the two cycles of the pump.

Memolub DS Electronic Box

TECHNICAL SPECIFICATIONS & SETTINGS

The output is settable from 2.25cc/3.375cc / 4.5cc and can develop a power of 120 bars with an air pressure of 6 bars thanks to a ratio of the latter of 1:20.

MEMOLUB DS
Dimensions 400 x 200 x 132mm
Power supply 24DC / 240 VAC / 0,3A min - 0.55A max
Protection 6A* circuit breaker
Power Cord 240VAC - 3G1.5 - Type H07RNF
Air input 6 bars - tube 4x6mm
T1 Time fixed at 1 min - ø6x8mm tube
T2 Ranging from 10min to 9999 min - ø4x6mm tube
Timer precision 0.2%
Working temperature -20°C to +55°C
Weight 1kg

INSTALLATION GUIDELINES

Electronic Box

Assembly of the MEMOLUB® DS PUMP (intermediate)

  • 1

    Screw a quick connection Ø8mm onto air input 1 (AIR IN T1) using a an Allen key

  • 2

    Screw a quick connection Ø6mm onto air input 2 (AIR IN T2) using a an Allen key

  • 3

    Screw a quick connection Ø8mm onto air output 1 (AIR OUT T1) using a an Allen key

  • 4

    Screw a quick connection Ø6mm onto air output 2 (AIR OUT T2) using a an Allen key

Assembly of the MEMOLUB® DS PUMP (stand-alone/last pump in series)

  • 1

    Screw a quick connection Ø8mm onto air input 1 (AIR IN T1) using a an Allen key

  • 2

    Screw a quick connection Ø6mm onto air input 2 (AIR IN T2) using a an Allen key

  • 3

    Screw an M 1/8”G stopper onto air output 1 (AIR OUT T1) using a an Allen key

  • 4

    Screw an M 1/8”G stopper onto air output 2 (AIR OUT T2) using a an Allen key

Assembly of the MEMOLUB® DS PUMP GREASING KIT

  • 1

    Screw the elbow adapter M 1/2ʺG to the pump's lubricant output

  • 2

    On the top output (2), put the conical M 1/4ʺG / straight M 1/4ʺG adapter (please leave the straight M 1/4ʺG of this adapter free for the connection with the high-pressure hose).

  • 3

    Valve in position, greasing mode (horizontally).

  • 1

    Check the components have not been damaged due to transport or handling.

  • 2

    Check the quality of the plastic bag containing the lubricant. This must not have any air bulges at the top of the container.

FAQ

  • Can I test the smooth functioning of my MEMOLUB® DS?

    Yes, the DS pump can be tested at any time by using its build in "check function". This process consists of operating a pump cycle manually, i.e. the two cycles (T1/T2) of the pump by shunting electronic timer.

    If you don't have the manual "check function" remote control, this test can be done by turning the electronic box's power off and on.

    Flip the red button of the manual "Check Function" command alternately with a time lapse of 10sec between each test.

    After every use of the "check function", please remove the remote control so the electronic box can switch to its operating mode.

  • How do I change the the lubricant container?

    The container is empty when there is no more pressure variation on the pump's output pressure gauge. (NB, this could also be a priming problem).

    A level gauge (see optional items) also provides visual information on the remaining lubricant volume. If the container is empty, follow these steps:

    • Cut the power to the electronic box
    • Remove the pump from its container, put its nozzle down in a protected area so that no dust and other dirt can get into it and damage the pump
    • Unscrew the container's lid and put it down on a clean surface
    • Prepare the new container: open it and carry out the various stages set out in Point 2.2.3 of this manual.
    • Connect the "check function"
    • Turn the electronic box's power back on
    • Re-prime the pump if needed: flip the valve of the greasing kit to "bleed" mode (see Section 2.2.2) and Operate the "check function" (see 2.4.3). The operation must be repeated to feed the grease through to the bleed outlet.
    • Stop and disconnect the "check function"
    • Flip the valve of the greasing kit to "greasing" mode
  • What to do when there is a priming problem

    If the pressure gauge at the pump output indicates zero pressure the pump can be un-primed. In this case, follow these steps:

    • Check whether there is any lubricant left in the container when you take the pump off
    • Re-prime the follower plate and get the air out as explained in Section 2.2.3.1.
    • Slide the pump through its lid and fix it to the container as explained in Section 2.2.3.2.
    • Flip the valve of the greasing kit to "bleed" mode (see section 2.2.2)
    • Connect and do the "check function" (see 2.4.3) The operation must be repeated to take the grease through to the bleed outlet
    • Stop and disconnect the "check function"
    • Flip the valve of the greasing kit to "greasing" mode

    If the pump does not re-prime after the above steps, contact your MEMOLUB® dealer.

  • What to do when there is a leak in the air network?

    • Cut the air supply line, i.e. set the FRL to zero bar (see air setting 3.1)
    • Disconnect the worn or defective tubes
    • Replace and reconnect the pipes correctly (see 2.4)
    • Return the FRL's air pressure to 6 bar
Memolub ds 1 2

Memolub® DS

  • Reusable multi-point lubrication system.
  • 24V powered.
  • 70 bar ejection pressure.
  • Up to 20 outlets.
  • Remote installation up to 20m.
  • PLC driven settings if desired.
  • Flexible pumping cycle settings.
More info